MPA4 - 4Door Access Control Solution (Europe)
Communications
- Built-in Communication Options Ethernet; RS-485
- I/O Expansion Module
Connectivity
- Use RS-485 Port to connect a maximum of 2 downstream I/O modules
- Controller Loop Capability EVL: 16 MPA2 or NetAXS123
- RS-485: 9 MPA2 and/or NetAXS123 panels total (8+1)
Readers/Doors
- Door/Reader Capability 2 Door/4 Readers - 4 Door/8 Readers(3)
- Expandability Expandable to 36 Doors/72 Readers per controller loop(1,2)
- Reader Compatibility OSDP:V2 and Standard Wiegand Protocol supported
Outputs
- 4 SPDT (jumper-selectable NO or NC contacts) per door rated at 3 A @ 28 VDC
- 4 Open Collector outputs (OC) rated at 16 mA @ 12 VDC: Reader LED (Aux)
- Reader Buzzer (Aux) per door are available
- Output Expandability Expandable to 36 total outputs using max. 2 NX4 Relay Output Boards(4)
- Relay Power Source Selectable: 12 VDC Self-Powered source or 0–28 VDC externally supplied source
Inputs
- 8 (+4) Configurable four-state supervised input points
- (Factory Default Settings are: Status, REX, Reader Tamper A, Reader Tamper B
- Ext. Tamper, and General Input)
- Input Expandability Inputs Expandable to 68
- Panel Tamper (3X) Panel Door, Off-Wall and External Tamper
- Power Inputs
- Unit Input 100 to 240 VAC, 50/60 Hz Input provides
- 13,8 VDC, 3.5 A Output, Battery Voltage Low Shutdown at 10.50V
- Socket or Hardware AC Input (IEC) MPA1002UMPS only
- Control Board Power Input 13,8 VDC (+/- 10%) from included Power Supply
Power Outputs
- Power for Locks/Strikes
- Reader(s)/Input Devices
- 1,25 A per door for locks/strikes, Readers, and Input Devices
- (2,5A @ 12VDC Total)
- Backup Battery System 12 VDC, 7 Ah Battery
- Enclosure
Material
- Metal
- Wiring Access Holes/Knockouts 24
Installation
- Removable Terminal Blocks with
- Colour-coded Labels Battery/PSU
- Graphic Wiring Info Cards/Labels Yes
- Captive Mounting Hardware Yes
System Information
- Real Time Clock Global Geographic Time Zone support; Daylight Saving Time support
- Clock Synchronization Yes: via NTP Network Server
- Processor IMX6-X1
- System Mean Time Between Failures 250,000 Hours
- Temperature Ratings Operating: 0°C to 49°C (32°F to 120°F)
- Storage: -55°C to 85°C (-67°F to 185°F)
- Humidity 93% Non-Condensing
- Lead Acid Batteries -40°C to 50°C (-40°F to 122°F)
- Certifications and Approvals EMC/CE and FCC Compliant; UL 294 Listing, ULC319
Physical
- Dimensions 14.1 inch (360 mm) x 16.1 inch (410 mm) x 4.3 inch (110 mm)
- Weight 6.0 Kg approx. (Battery not included - Includes Control Panel and Power Supply)